Total views : 222

Heart Rate Measuring and Performance Evaluation from Carotid Artery and Occipital Artery According to Posture during Sleep Using Multiple Photo Plethysmo Gram (PPG) Sensor

Affiliations

  • Student, Department of Electrical, Electronic and Information Comm. Engineering, Graduated School of Tongmyong University, 428, Sinseon-ro. Nam-gu, Busan, Korea, Republic of
  • Student, Department of Computer Software, University of Science and Technology, 217,Gajeong-ro. Yuseong-gu, Daejeon, Korea, Republic of
  • Professor, Department of Electronic Engineering, Tongmyong University, 428, Sinseon-ro. Nam-gu, Busan, Korea, Republic of

Abstract


Objectives: This paper will suggest that heart rate can be measured without motion artifacts even when the sleeping position is not constrained, but changes. Methods/Statistical Analysis: It was implement a heart rate measurement system, using the multiple Photo Plethysmo Gram (PPG) sensor and Fast Fourier Transform (FFT). And in experiments using the implemented system, it comparatively evaluates the performance of measuring heart rates at the carotid artery and the occipital artery around the neck according to changed sleeping positions against the performance of measuring heart rates at the finger. Findings: The deviations of heart rates measured at the carotid artery (1 minute: 1.07-6.21 bpm, 10 minutes: 0.57-5.18 bpm) and heart rates measured at the occipital artery (1 minute: 0.46-3.96 bpm, 10 minutes: 0.34- 5.2 bpm) from heart rate measured at the finger were found to be relatively low, with max 6.21 bpm at the carotid artery and max 5.2 bpm at the occipital artery. If heart rate had been found to be 0 or an abnormally high value, the deviation from heart rate at the finger would have shown a great difference. From this, It was found that there is almost no difference in the performance of heart-rate measurement the carotid artery and the occipital artery around the neck between the finger. Therefore, this paper suggested that it is possible to measure heart rates without noise even when sleeping positions are unconstrained and are subjected to changes. Improvements/Applications: From this, Can be measured during sleep, the unconstrained use heart rate in a variety of situations.

Keywords

Carotid Artery, Heart Rate Measurement, Multiple Sensor, Occipital Artery, Photo Plethysmo Gram (PPG), Sleep.

Full Text:

 |  (PDF views: 201)

References


  • Seoul Met Area Population to Decline from 2030. http://www.koreaittimes.com/story/43236/seoul-met-area-population-decline-2030nso. Date Accessed: 13/12/2014.
  • Kim JH, Kang HS, Jeong DU. Implementation and Estimation of the Wearable PTT Monitoring System Using Wireless Sensor Network. The Korean Institute of Maritime Information and Communication Sciences, 2010.
  • Jang MS, Eom SH, Kim PS, Lee EH. Design and Implementation of Mobile Terminal with Multi Bio-signal Measurement for u-Healthcare System. Rehabilitation Engineering and Assistive Technology Society of Korea. 2013 Dec; 7(2):27-34.
  • Youn JY, Jeong DU. Implementation of the Multi-channel Vital Signal Monitoring System for Home Healthcare. The Korea Institute of Signal Processing and Systems. 2010 Jul; 11(3):198-99.
  • Lee JY. The Heart Rate Monitoring System using Inverted Photoplethysmography. Korea Society of Computer Information. 2012 Mar; 17(3): 105-11.
  • Cha JY, Choi HS, Shin JY, Lee KJ. Development of PPG Pillow System for Unconstrained Respiration and Heart Rate Monitoring during Sleep. Conference on the Korea Institute of Electronics and Information Engineers. 2008; 31(1):1101-02.
  • Kim TK. A Study on the Measurement Method of Pulse Oximetry by Using FFT (Fast Fourier Transform). Major in Applied Electrical Engineering, Sangji University. 2012 Jul, 2, p.1-3.
  • Lee YK, Shin HS, Jo J. Development of a PPG array sensor module. The Institute of Electronics and Information Engineers. 2010; 33(1):1368-70.
  • Nam SY, Ham CY, Kwon SR, Shin HS. Design and Implementation of PPG Measurement System, The Korean Institute of Communications and Information Sciences. 2015; 8(7):469-70.
  • Financial News. http://www.fnnews.com/news/201008091444144404. Date accessed: 09/08/2010.

Refbacks

  • There are currently no refbacks.


Creative Commons License
This work is licensed under a Creative Commons Attribution 3.0 License.