A Study for the Reproducibility of Detachable Coil used in Cerebral Aneurysm Coil Embolization

Affiliations

  • Department of Health Care, Hanseo University, Seosan, Korea, Republic of

Abstract


Background/Objectives: In this study, the outer diameter of the detachable coil used for cerebral aneurysm coil embolization was evaluated objectively through quantitative analysis. Methods/Statistical Analysis: Out of the helical shape coils from three companies that had failed coil embolization from January 2012 to May 2015, the outer diameter of 120 coils (20 from each company) with the diameter of 1.5 mm, and 2.0 mm were measured with an optical microscope and compared with the outer diameter of the coil before insertion. Findings: For the coils from all three companies, there were not any significant changes for the outer diameter after keeping the coils in a water bath at 37℃ for 10 and 20 minutes, respectively. For the 1.5 mm sized coils, the average outer diameters before insertion were 1,860μm for coils from company S, 1,530μm for C and 1,554μm for M. Similarly, for the 2.0 mm sized coils, the averages were 2,372μm for company S, 2,038μm for C, and 2,056μm for M, which were larger than the sizes proposed by the companies. After failure, the average changes in outer diameter were 2,074μm for company S, 1,535μm for C and 1,558μm for M measured for the 1.5 mm sized coils, and 2,581μm for company S, 2,043μm for C, and 2,062μm for M among the 2.0 mm sized size coils. The change in the average was the largest for coils from company S, which showed a statistical significance (p<0.05). Also, the shorter the length of a given coil, the smaller the changes seen in the diameter. Application/Improvements: The coils from companies C and M maintained reproducibility; that is, they maintained the original shape after the insertion failure, and did not show significant changes in the outer diameter.

Keywords

Cerebral Aneurysm Coil Embolization, Coil Diameter, Detachable Coils, Reproducibility.

Full Text:

 |  (PDF views: 158)

References


  • Choi Byung Yon. Management of Traumatic Cerebral Aneurysms. Kor J Cerebrovascular Disease. 1999; 1(1):4349.
  • Chae Soo-In. Hanseo University: Characteristic of Coils According to Volume in Case of Embolization of Cerebral Aneurysm. 2012.
  • Molyneux A, Kerr R, Stratton I, Sandercock P. International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised trial. Lancet. 2002; 360:1267-74.
  • Jong Tae-Shik. Chonbuk National University: Endovascular Treatment of Cerebral Aneurysms with Detachable Coils. 2007.
  • Byun Hong Sik. Recent Trends in Treatment of Cerebral Aneurysms: Comparison between Endovascular Coil Embolization and Surgical Clipping. Neurointervention. 2009; 4(1):1-5.
  • Friedman JA, et al. Guglielmi detachable coil treatment of ruptured saccular cerebral aneurysms: retrospective review of a 10-year single-center experience. AJNR Am J Neuroradiol. 2003; 24:526-33.
  • Gallas S, Pasco A, Cottier JP, et al. A multicenter study of 705 ruptured intracranial aneurysms treated with Guglielmi detachable coils. AJNR Am J Neuroradiol. 2005; 26:1723-31.
  • Murayama Y, et al. Guglielmi detachable coil embolization of cerebral aneurysms; 11 years experience. J Neurosurg. 2003; 98(5):959-66.
  • Han Moon Hee, Kwon Bae Ju, Jung Chul Kyu, Shin Seung Hoon, Cho Jae Hoon. Endovascular Treatment of Cerebral Aneurysms: Detachable Coils and General Principles. Neuro-Intervention. 2006; 1(1):1-6.
  • Health Insurance Review and Assessment Service. 2015. Available from: http://opendata.hira.or.kr/home.do.
  • Han Moon Hee, Kwon Bae Ju, Jung Chul Kyu, Shin Seung Hoon, Cho Jae Hoon. Endovascular Treatment of Cerebral Aneurysms: Coiling Techniques, Neurointervention. 2007; 2(1):1-11.
  • Kwon Yang. Endovascular Complication and Its Management in Intracranial Aneurysm. J Korean Neurosurg Soc. 2000; 29(1):1121-25.
  • Park Ye-Woon, Lim Cheong-Hwan, Jung Hong-Ryang, et al. Appropriate Inspection Distance of Digital X-ray Imaging Equipment for Diagnosis. Indian Journal of Science and Technology. 2015; 8(Supp. 8):380-86.
  • Kim Chang-Gyu. The Application of a Water Filter to Reduce Radiation Bone Mineral Densitometry(BMD). Indian Journal of Science and Technology. 2015; 8(Supp.9):352-57.

Refbacks

  • There are currently no refbacks.


Creative Commons License
This work is licensed under a Creative Commons Attribution 3.0 License.